Shopping Cart
By continuing to browse this website, you agree to our use of cookies and to the processing of your personal data in accordance with the GDPR.
View more details
Our website is getting a makeover. Some pages may look different for a few days: orders and payments work as usual.
Our website is getting a makeover. Some pages may look different for a few days: orders and payments work as usual.
Onduleur On-line Liebert GXT5 6000VA RT6U
Essential, affordable UPS for high-performance power protection. The Vertiv™ Liebert® GXE UPS is an on-line double conversion solution that provides power protection in an affordable, efficient system, with flexibility of deployment and operation.
The high efficiency of the on-line and ECO operating modes of this very affordable UPS also helps save energy and operating costs
Available in 6 or 10 kVA power ratings, it offers mounting flexibility in tower position or inside a rack cabinet, together with the IT equipment essential to any application.
In addition, the ability to add external battery cabinets provides extended runtime for applications requiring an even longer backup period in the event of mains outages.
In addition to the extended runtime, the many available monitoring options make this compact UPS the ideal tool for providing the best electrical protection to equipment deployed at the edge of networks or at remote sites.
Vertiv™ Liebert® GXE 6kVA with optional 2U external battery cabinet
Features of the Vertiv™ Liebert® GXE
y High output power factor (1.0)
y Rotating color LCD graphic display
y High efficiency (up to 94%) in on-line mode
y Even higher efficiency (up to 98%) in ECO mode
y Flexible rack/tower design, with rack-mounting kit included
y Extended runtime with up to 4 external battery cabinets (EBC)
y Internal UPS batteries that can be hot-swapped by the user
y Easy to install, configure and use
y Remote management capability with optional Vertiv™
Liebert® Intellislot™IS-UNITY network management cards
y Wide input frequency operation (40-70 Hz) without
power derating
y Automatic internal bypass
y Free UPS management software
y Fast recharge time (3 hours to 90%)
y Compatible with Vertiv™LIFE™ Services to optimize
UPS availability
Available in 6 or 10 kVA power ratings, it offers mounting flexibility in tower position or inside a rack cabinet, together with the IT equipment essential to any application.
In addition, the ability to add external battery cabinets provides extended runtime for applications requiring an even longer backup period in the event of mains outages.
In addition to the extended runtime, the many available monitoring options make this compact UPS the ideal tool for providing the best electrical protection to equipment deployed at the edge of networks or at remote sites.
Vertiv™ Liebert® GXE 6kVA with optional 2U external battery cabinet
Features of the Vertiv™ Liebert® GXE
y High output power factor (1.0)
y Rotating color LCD graphic display
y High efficiency (up to 94%) in on-line mode
y Even higher efficiency (up to 98%) in ECO mode
y Flexible rack/tower design, with rack-mounting kit included
y Extended runtime with up to 4 external battery cabinets (EBC)
y Internal UPS batteries that can be hot-swapped by the user
y Easy to install, configure and use
y Remote management capability with optional Vertiv™
Liebert® Intellislot™IS-UNITY network management cards
y Wide input frequency operation (40-70 Hz) without
power derating
y Automatic internal bypass
y Free UPS management software
y Fast recharge time (3 hours to 90%)
y Compatible with Vertiv™LIFE™ Services to optimize
UPS availability
- UPS Brand
- new
- Type of use
- new
new - Technology
- ON-LINE Double conversion
- Output Waveform
- SineWave
- Format
- Rack/tower convertible (rails included)
- Power in VA
- 6000
- Power in Watts
- 6000
- Display
- LCD screen
- Rack
- 4 U
- Rail kit included
- Yes
- Input voltage
- 230V Single phase
- Output voltage
- 230V single-phase
- Expandable Autonomy
- Oui
- Additional card slot
- Oui
- Output connector (protected)
- Terminal block
- Input connector
- Hardwired
- Communication port(s)
- USB
- Bypass
- Internal automatic By-Pass
- Warranty
- 2 years
| Ease of management | |||||||||
|---|---|---|---|---|---|---|---|---|---|
| Network manageable | Provides remote power management of the UPS over the network via Powerchute Business Edition. | ||||||||
| Compatible with InfraStruXure Manager | Enables centralized management via APC's InfraStruXure Manager. | ||||||||
| SmartSlot | Customize the capabilities of your UPS with management cards. | ||||||||
| LED status indicators | Gives a quick view of the power and unit status through visual indicators. | ||||||||
| Serial connectivity | Allows the UPS to be managed via a serial port. | ||||||||
| Availability | |||||||||
| Scalable runtime | Allows the runtime to be increased quickly when needed. | ||||||||
| Automatic internal bypass | Supplies mains power to the connected loads in the event of an overload or a UPS failure. | ||||||||
| Hot-swappable batteries | Ensures continuity and quality of the power supply to the protected equipment while the batteries are being replaced. | ||||||||
| Intelligent battery management | Maximizes battery performance, lifetime and reliability through an intelligent, precision charging process. | ||||||||
| Temperature-compensated battery charging | Extends battery life by regulating the charge voltage according to the actual temperature of the batteries. | ||||||||
| Automatic restart of loads after UPS shutdown | Automatically restarts the connected equipment when mains power is restored. | ||||||||
| Protection | |||||||||
| Power conditioning | Protects the connected loads against surges, spikes, lightning and other electrical disturbances. | ||||||||
| Input power factor correction | Minimizes installation costs by allowing the use of smaller generators and cables. | ||||||||
| Frequency and voltage regulation | Increases application availability by correcting abnormal frequencies and voltages without drawing on the battery. | ||||||||
| Cold start capability | Provides temporary battery power in the event of a mains failure. | ||||||||
| Generator compatible | Ensures a stable, constant supply of current to protect your equipment when a generator is used. | ||||||||
| Safety agency approved | Ensures the product has been tested and approved as able to operate safely with the connected loads and within the environment. | ||||||||
| Resettable circuit breaker | Easy recovery after a surge; no need to replace a fuse. | ||||||||
| Ease of maintenance | |||||||||
| Predictive failure notification | Provides an early-warning failure analysis function that allows components to be replaced proactively. | ||||||||
| User-replaceable batteries | Increases availability by allowing a trained user to upgrade and replace the batteries, thereby reducing repair times. | ||||||||
| Disconnected battery notification | Warns when a battery is not available to provide backup power. | ||||||||
| Audible alarms | Reports changes in mains power and UPS conditions. | ||||||||
| Automatic self-test | The battery self-test is performed periodically to ensure early detection of the need to replace a battery. | ||||||||
| Adaptability | |||||||||
| Flash-upgradable firmware | Firmware maintenance releases can be installed remotely via FTP. | ||||||||
| Rack/Tower convertible | Protects the initial investment in the UPS when migrating from a tower environment to a rack environment. | ||||||||
| Plug-and-Play external batteries | Ensures a stable, constant supply of current to the loads while the UPS runtime is being increased. | ||||||||