Compaq 1000 / 2000 / 3000 series

The very first Compaq UPS for ProLiant servers: T700h, T1000h, T1500h, R1500h, T2400h and R3000h ("h" stands for the 230 V versions). Listed so you can find the right replacement battery from the Compaq part number.
Compaq 1000 / 2000 / 3000 series UPS
What are they used for?
Line-interactive technology adds an automatic voltage regulator (AVR): voltage dips and surges are corrected without drawing on the battery, which preserves runtime and battery life. It is the right compromise for demanding workstations, small servers, network racks and CCTV.
Key features of the range
- Technology: Line interactive
- Waveform on battery: Sine wave
- Form factor: Tower, 19" rack
- Network / SNMP card slot
- Runtime extendable with ERM module
- Automatic voltage regulation (AVR)
Models in the range
| Model | HP P/N | Power | Internal batteries | HP spare battery |
|---|---|---|---|---|
| Compaq T700h | 295372-B22 | 700 VA / 420 W | 2 x 12 V 7 Ah | – |
| Compaq T1000h | 242688-002 | 1 000 VA / 670 W | 4 x 6 V 12 Ah | 295460-001 |
| Compaq T1500h | 242688-004 | 1 500 VA / 960 W | 2 x 12 V 17 Ah | 340795-001 |
| Compaq R1500h | 242704-002 | 1 500 VA / 960 W | 4 x 12 V 7 Ah | 295463-001 |
| Compaq T2400h | 242688-006 | 2 300 VA / 1 600 W | 4 x 12 V 17 Ah | 295461-001 |
| Compaq R3000h | 242705-002 | 3 000 VA / 2 250 W | 16 x 6 V 12 Ah | 295462-001 |
Model no longer sold by HP: listed to help you identify your UPS and find its replacement battery kit.
Choosing the right UPS
- Add up the power in watts (W) of the equipment to protect and keep a margin of about 30%: the UPS should not run permanently above 70 to 80% of its rating.
- Check the number and type of outlets (IEC C13, C19, Schuko, terminal block) against your equipment's power cords.
- For longer runtime, choose a model with extendable runtime or an ER version to connect to battery cabinets.
- For automatic and clean shutdown of your servers, use the USB/RS232 port or a network card in the communication slot.
Replacement batteries
UPS batteries wear out even when there are few power cuts: they should be replaced on average every 3 to 5 years. You will find the replacement battery kits for this range in the « HP UPS batteries » section, sorted by generation and with the HP spare battery part number.