NPP NP12-12Ah VdS battery – 12 V 12 Ah AGM (copie)
NPP 12 V 12 Ah AGM battery, model NP12-12Ah VdS. The NP series is NPP's all-round range: a sealed, valve-regulated lead-acid (VRLA) battery whose electrolyte is fully held in absorbent glass mat separators (AGM technology).
Dimensions: 151 × 98 × 101 mm, 3.4 kg.
The NP series is NPP's all-round range: a sealed, valve-regulated lead-acid (VRLA) battery whose electrolyte is fully held in absorbent glass mat separators (AGM technology). It needs no maintenance and is suitable both for permanent standby (float) use and for light cycling.
This model is VdS certified, the German approval required for intrusion alarm and fire detection systems.
Key features
- Sealed AGM technology, no water top-up ever
- Heavy-duty grids for long-lasting performance
- Low self-discharge: 3% per month maximum at 25 °C
- Operates from –20 °C to +50 °C (ideal: 25 °C)
Applications
- UPS and backup power supplies
- Alarms, access control and CCTV
- Emergency lighting and fire detection
- Medical equipment and instrumentation
- Telecommunications and IT
- Toys and small electric vehicles
Technical specifications – NP12-12Ah VdS
| Technology | Sealed lead-acid AGM (VRLA) |
|---|---|
| Nominal voltage (V) | 12 |
| Capacity (Ah / 20hr) | 12 |
| Capacity (Ah / 10hr) | 11 |
| Capacity (Ah / 3hr) | 8.7 |
| Internal resistance (mΩ) | 19 |
| Terminals | T1 (Faston 4.75 mm) or T2 (Faston 6.35 mm) |
| Eurobat design life (years) | 3 to 5 |
| Float charging voltage | 13.6 – 13.8 V |
| Cyclic charging voltage | 14.5 – 15.0 V |
| Max. discharge current (5 s) | 180 A |
| Max. charging current | 3.6 A |
| Length (mm) | 151 |
| Width (mm) | 98 |
| Total height incl. terminals (mm) | 101 |
| Weight (kg) | 3.4 |
| Warranty | 2 years |
Good to know
A lead-acid battery must be stored charged: when in stock, recharge it every 3 to 6 months and never leave it discharged. Heat greatly shortens its life: above 25 °C, it is roughly halved for every 10 °C. When replacing batteries in a UPS, change them all at the same time, with models of the same capacity.
Manufactured to IEC 60896-21/22, compliant with Eurobat, RoHS, WEEE and REACH requirements, CE marked.
Documentation
The manufacturer's datasheet and the safety and compliance documents can be downloaded from the Documents tab of this page.
- Type of product
- Single battery (sold individually)
- Life time (Year)
- 3 to 5
- Battery Type
- Sealed lead-acid AGM (VRLA)
- Width (mm)
- 151
- Height (mm)
- 101
- Depth (mm)
- 98
- Voltage (V)
- 12
- Capacity (Ah /20 hr)
- 12
- Terminals
- T1 (Faston 4.75 mm) or T2 (Faston 6.35 mm)
- Weight (Kg)
- 3.4
- Warranty
- 2 years
- Battery range
- NP – General purpose AGM
- Capacity (Ah / 10hr)
- 11
- Capacity (Ah / 3hr)
- 8.7
- Internal resistance (mΩ)
- 19
- Float charging voltage
- 13.6 – 13.8 V
- Cyclic charging voltage
- 14.5 – 15.0 V
- Max. charging current
- 3.6 A
- Max. discharge current (5 s)
- 180 A
NPP Power manufactures sealed lead-acid (AGM, AGM-Gel) and LiFePO4 lithium batteries for UPS, security, solar, telecom and electric mobility applications.
| Ease of management | |||||||||
|---|---|---|---|---|---|---|---|---|---|
| Network manageable | Provides remote power management of the UPS over the network via Powerchute Business Edition. | ||||||||
| Compatible with InfraStruXure Manager | Enables centralized management via APC's InfraStruXure Manager. | ||||||||
| SmartSlot | Customize the capabilities of your UPS with management cards. | ||||||||
| LED status indicators | Gives a quick view of the power and unit status through visual indicators. | ||||||||
| Serial connectivity | Allows the UPS to be managed via a serial port. | ||||||||
| Availability | |||||||||
| Scalable runtime | Allows the runtime to be increased quickly when needed. | ||||||||
| Automatic internal bypass | Supplies mains power to the connected loads in the event of an overload or a UPS failure. | ||||||||
| Hot-swappable batteries | Ensures continuity and quality of the power supply to the protected equipment while the batteries are being replaced. | ||||||||
| Intelligent battery management | Maximizes battery performance, lifetime and reliability through an intelligent, precision charging process. | ||||||||
| Temperature-compensated battery charging | Extends battery life by regulating the charge voltage according to the actual temperature of the batteries. | ||||||||
| Automatic restart of loads after UPS shutdown | Automatically restarts the connected equipment when mains power is restored. | ||||||||
| Protection | |||||||||
| Power conditioning | Protects the connected loads against surges, spikes, lightning and other electrical disturbances. | ||||||||
| Input power factor correction | Minimizes installation costs by allowing the use of smaller generators and cables. | ||||||||
| Frequency and voltage regulation | Increases application availability by correcting abnormal frequencies and voltages without drawing on the battery. | ||||||||
| Cold start capability | Provides temporary battery power in the event of a mains failure. | ||||||||
| Generator compatible | Ensures a stable, constant supply of current to protect your equipment when a generator is used. | ||||||||
| Safety agency approved | Ensures the product has been tested and approved as able to operate safely with the connected loads and within the environment. | ||||||||
| Resettable circuit breaker | Easy recovery after a surge; no need to replace a fuse. | ||||||||
| Ease of maintenance | |||||||||
| Predictive failure notification | Provides an early-warning failure analysis function that allows components to be replaced proactively. | ||||||||
| User-replaceable batteries | Increases availability by allowing a trained user to upgrade and replace the batteries, thereby reducing repair times. | ||||||||
| Disconnected battery notification | Warns when a battery is not available to provide backup power. | ||||||||
| Audible alarms | Reports changes in mains power and UPS conditions. | ||||||||
| Automatic self-test | The battery self-test is performed periodically to ensure early detection of the need to replace a battery. | ||||||||
| Adaptability | |||||||||
| Flash-upgradable firmware | Firmware maintenance releases can be installed remotely via FTP. | ||||||||
| Rack/Tower convertible | Protects the initial investment in the UPS when migrating from a tower environment to a rack environment. | ||||||||
| Plug-and-Play external batteries | Ensures a stable, constant supply of current to the loads while the UPS runtime is being increased. | ||||||||