Shopping Cart
By continuing to browse this website, you agree to our use of cookies and to the processing of your personal data in accordance with the GDPR. View more details
Our website is getting a makeover. Some pages may look different for a few days: orders and payments work as usual.
Our website is getting a makeover. Some pages may look different for a few days: orders and payments work as usual.
APC Smart-UPS C 1500VA 2U Rack mountable LCD 230V
APC Smart-UPS 1,500 VA UPS, 230 V, LCD display, rack mount, 2U, with SmartConnect
Intelligent, efficient network power protection, from entry-level equipment to equipment with scalable runtime. Ideal for servers, point-of-sale equipment, routers, switches, hubs and other network devices.
Includes: software CD, documentation CD, USB cable
APC Smart-UPS 1500 VA UPS, 230 V, LCD display, rack mount, 2U, with SmartConnect
Intelligent and efficient mains power protection, from entry-level up to equipment with scalable runtime. Ideal for servers, point-of-sale equipment, routers, switches, hubs and other network devices.
Includes: software CD, documentation CD, USB cable
- Cold start capable Provides temporary battery power in the event of a mains failure.
- Green mode Patent-pending operating mode that bypasses unused electrical components in good condition to achieve high efficiency without compromising safety.
- High online efficiency Lowers the total cost of ownership and produces less heat.
- Status display on LCD screen Shows the main UPS statuses at a glance. Multiple status indicators with bar graphs representing the loads and the batteries.
- Pure sine wave output on battery Simulates mains power to offer the highest degree of compatibility with sensitive electronic equipment and active servers fitted with power factor correction (PFC).
- SmartConnect Innovative, easy-to-use remote monitoring feature that provides automatic notifications, firmware updates and advanced support services.
- Temperature-compensated battery charging Extends battery runtime by regulating the charge voltage according to the actual battery temperature.
Smart-UPS Features and benefits
Marketing features
Optimized productivity, adaptable to your specific application needs
An intuitive interface provides clear information and allows the UPS to be configured locally using simple, easy-to-use navigation keys. More than 15 different programmable settings, including controlled outlet groups, allow application-specific settings, thresholds and notifications.
Save time with easy and convenient remote access
Network manageable via a serial port, a USB port or an optional Ethernet port. Includes PowerChute® Business Edition software, which makes monitoring and control easier, secures operating system shutdown and offers innovative power management capabilities.
Peace of mind through complete equipment reliability and compatibility
Provides a pure sine wave output, recommended by server manufacturers that use power supplies with active power factor correction (PFC). Safety tested and approved by an independent agency: you can therefore deploy Smart-UPS with the assurance that it meets or exceeds the most stringent industry standards.
Low operating and maintenance costs with high efficiency, proven reliability and intelligent battery management
An energy-saving operating mode reaches an efficiency level above 97%. Smart-UPS was the first Energy Star certified network UPS. Intelligent battery management, pioneered by APC, optimizes battery performance and life through precise, intelligent temperature-compensated charging. A dynamic battery replacement date indicator and automatic self-tests ensure battery reliability and warn when a replacement will be needed. Hot-swappable battery modules, easy and convenient to plug in, allow the battery to be replaced without powering down. Designed and manufactured by APC for more than 23 years, Smart-UPS is the most widely used network UPS in the world, with more than 25 million units sold.
Avoids costly power problems by keeping your IT equipment and data secure and available
Network-grade power conditioning protects against surges and annoying noise. A solid-state automatic voltage regulator can boost a low input voltage by 30% and reduce a high voltage by 12%, without any battery operation. Reliable backup battery power capability during power outages or extended system shutdowns
Availability
Battery disconnected notification
Warns when a battery is not available to provide backup power.
Automatic self-test
The battery self-test is performed periodically to ensure early detection of the need to replace a battery.
Automatic voltage regulation (AVR) by boost and trim
Increases application availability by correcting voltage sags and overvoltages without drawing on the battery.
Intelligent battery management
Maximizes battery performance, life and reliability through an intelligent, precision recharging process.
Power conditioning
Protects connected loads against surges, spikes, lightning and other electrical disturbances.
Temperature-compensated battery charging
Extends battery runtime by regulating the charge voltage according to the actual battery temperature.
Automatic restart of loads after UPS shutdown
Automatically restarts the connected equipment when mains power is restored.
Ease of management
USB connectivity
Enables UPS management via a USB port.
Audible alarms
Warns when the unit is running on battery, when the battery is low or when there is an overload.
Network manageable
Provides remote power management of the UPS over the network via PowerChute Business Edition.
Serial connectivity
Enables UPS management via a serial port.
LED status indicators
Lets you quickly check the power and unit status using visual indicators.
Battery disconnected notification
Warns when a battery is not available to provide backup power.
Ease of maintenance
Battery failure notification
Provides a battery failure analysis function with early warning, allowing preventive maintenance to be carried out in time
Resettable circuit breakers
Allows quick recovery after an overload.
Hot-swappable batteries
Ensures the continuity and quality of the power supplied to the protected equipment during battery replacement.
Predictive failure notification
Provides a failure analysis function with early warning, allowing components to be replaced proactively.
User-replaceable batteries
Increases availability by allowing a trained user to upgrade and replace the batteries, thus reducing repair times.
Safety
Approved by a safety agency
Guarantees that the product has been tested and approved as able to operate safely with the connected loads and within the environment.
Adaptability
Adjustable voltage sensitivity
Allows you to adapt your UPS optimally and efficiently to specific power supply systems or specific generator sets.
Adjustable voltage transfer points
Maximizes the life of your batteries by widening the input voltage range or by strictly controlling the output voltage.
- Type of use
- Server
| Ease of management | |||||||||
|---|---|---|---|---|---|---|---|---|---|
| Network manageable | Provides remote power management of the UPS over the network via Powerchute Business Edition. | ||||||||
| Compatible with InfraStruXure Manager | Enables centralized management via APC's InfraStruXure Manager. | ||||||||
| SmartSlot | Customize the capabilities of your UPS with management cards. | ||||||||
| LED status indicators | Gives a quick view of the power and unit status through visual indicators. | ||||||||
| Serial connectivity | Allows the UPS to be managed via a serial port. | ||||||||
| Availability | |||||||||
| Scalable runtime | Allows the runtime to be increased quickly when needed. | ||||||||
| Automatic internal bypass | Supplies mains power to the connected loads in the event of an overload or a UPS failure. | ||||||||
| Hot-swappable batteries | Ensures continuity and quality of the power supply to the protected equipment while the batteries are being replaced. | ||||||||
| Intelligent battery management | Maximizes battery performance, lifetime and reliability through an intelligent, precision charging process. | ||||||||
| Temperature-compensated battery charging | Extends battery life by regulating the charge voltage according to the actual temperature of the batteries. | ||||||||
| Automatic restart of loads after UPS shutdown | Automatically restarts the connected equipment when mains power is restored. | ||||||||
| Protection | |||||||||
| Power conditioning | Protects the connected loads against surges, spikes, lightning and other electrical disturbances. | ||||||||
| Input power factor correction | Minimizes installation costs by allowing the use of smaller generators and cables. | ||||||||
| Frequency and voltage regulation | Increases application availability by correcting abnormal frequencies and voltages without drawing on the battery. | ||||||||
| Cold start capability | Provides temporary battery power in the event of a mains failure. | ||||||||
| Generator compatible | Ensures a stable, constant supply of current to protect your equipment when a generator is used. | ||||||||
| Safety agency approved | Ensures the product has been tested and approved as able to operate safely with the connected loads and within the environment. | ||||||||
| Resettable circuit breaker | Easy recovery after a surge; no need to replace a fuse. | ||||||||
| Ease of maintenance | |||||||||
| Predictive failure notification | Provides an early-warning failure analysis function that allows components to be replaced proactively. | ||||||||
| User-replaceable batteries | Increases availability by allowing a trained user to upgrade and replace the batteries, thereby reducing repair times. | ||||||||
| Disconnected battery notification | Warns when a battery is not available to provide backup power. | ||||||||
| Audible alarms | Reports changes in mains power and UPS conditions. | ||||||||
| Automatic self-test | The battery self-test is performed periodically to ensure early detection of the need to replace a battery. | ||||||||
| Adaptability | |||||||||
| Flash-upgradable firmware | Firmware maintenance releases can be installed remotely via FTP. | ||||||||
| Rack/Tower convertible | Protects the initial investment in the UPS when migrating from a tower environment to a rack environment. | ||||||||
| Plug-and-Play external batteries | Ensures a stable, constant supply of current to the loads while the UPS runtime is being increased. | ||||||||