Hot-Swap Maintenance Bypass with 4 French output sockets MBP3KIF
High availability for any UPS up to 3kVA
. Thanks to the HotSwap MBP (Maintenance By-Pass), any UPS under 3 kVA can benefit from the "hot swap" function: replacing or upgrading a UPS takes place with no interruption whatsoever to the protected application!
. With its IEC16A plug connection and locking system, this external bypass module is compatible with any UPS, today and tomorrow, from MGE or from any other manufacturer.
. The HotSwap MBP range offers several types of output connection:
- via FR, DIN, BS or IEC sockets
- via terminal blocks on the HW (Hard-Wired) version.
. HotSwap MBPs can be installed, as required, at the back of the UPS, on the sides, on top, or in a rack (1.5 U horizontal mounting or zero-U vertical mounting).
Technical specifications
| Installation modes | In a 19" rack, horizontally or vertically (zero U), or on MGE RT-format UPS |
| Voltage | 220-230-240-250 V |
| UPS connection | Input: IEC 16A socket |
| Input connection | IEC C20 (16A) |
| Output connection | 4 French-type sockets |
| Dimensions in mm (WxHxD) | 483x52x120 |
| Manufacturer warranty | 2 years |
| Ease of management | |||||||||
|---|---|---|---|---|---|---|---|---|---|
| Network manageable | Provides remote power management of the UPS over the network via Powerchute Business Edition. | ||||||||
| Compatible with InfraStruXure Manager | Enables centralized management via APC's InfraStruXure Manager. | ||||||||
| SmartSlot | Customize the capabilities of your UPS with management cards. | ||||||||
| LED status indicators | Gives a quick view of the power and unit status through visual indicators. | ||||||||
| Serial connectivity | Allows the UPS to be managed via a serial port. | ||||||||
| Availability | |||||||||
| Scalable runtime | Allows the runtime to be increased quickly when needed. | ||||||||
| Automatic internal bypass | Supplies mains power to the connected loads in the event of an overload or a UPS failure. | ||||||||
| Hot-swappable batteries | Ensures continuity and quality of the power supply to the protected equipment while the batteries are being replaced. | ||||||||
| Intelligent battery management | Maximizes battery performance, lifetime and reliability through an intelligent, precision charging process. | ||||||||
| Temperature-compensated battery charging | Extends battery life by regulating the charge voltage according to the actual temperature of the batteries. | ||||||||
| Automatic restart of loads after UPS shutdown | Automatically restarts the connected equipment when mains power is restored. | ||||||||
| Protection | |||||||||
| Power conditioning | Protects the connected loads against surges, spikes, lightning and other electrical disturbances. | ||||||||
| Input power factor correction | Minimizes installation costs by allowing the use of smaller generators and cables. | ||||||||
| Frequency and voltage regulation | Increases application availability by correcting abnormal frequencies and voltages without drawing on the battery. | ||||||||
| Cold start capability | Provides temporary battery power in the event of a mains failure. | ||||||||
| Generator compatible | Ensures a stable, constant supply of current to protect your equipment when a generator is used. | ||||||||
| Safety agency approved | Ensures the product has been tested and approved as able to operate safely with the connected loads and within the environment. | ||||||||
| Resettable circuit breaker | Easy recovery after a surge; no need to replace a fuse. | ||||||||
| Ease of maintenance | |||||||||
| Predictive failure notification | Provides an early-warning failure analysis function that allows components to be replaced proactively. | ||||||||
| User-replaceable batteries | Increases availability by allowing a trained user to upgrade and replace the batteries, thereby reducing repair times. | ||||||||
| Disconnected battery notification | Warns when a battery is not available to provide backup power. | ||||||||
| Audible alarms | Reports changes in mains power and UPS conditions. | ||||||||
| Automatic self-test | The battery self-test is performed periodically to ensure early detection of the need to replace a battery. | ||||||||
| Adaptability | |||||||||
| Flash-upgradable firmware | Firmware maintenance releases can be installed remotely via FTP. | ||||||||
| Rack/Tower convertible | Protects the initial investment in the UPS when migrating from a tower environment to a rack environment. | ||||||||
| Plug-and-Play external batteries | Ensures a stable, constant supply of current to the loads while the UPS runtime is being increased. | ||||||||