UPS EMERSON Liebert TRI TRI / TRI MONO 15 kVA Runtime 27 min
EMERSON UPS TRI TRI / TRI MONO 15 kVA Runtime 27 min
Liebert NXC is a compact solution designed to optimize the use of space and offer improved flexibility, in order to ensure better protection for all types of loads (capacitive or inductive).
Its low THDi (< 5%) and its input power factor correction ensure that the UPS draws less current from the upstream distribution network, which eliminates the need to increase the capacity of the generator set and other equipment.
Liebert NXC offers improved flexibility thanks to:
- A fully galvanic isolation option
- Single-phase or three-phase output configuration options
- An individual or shared battery cabinet
- A reduced footprint
Output configuration
Liebert NXC can be configured on site to provide a three-phase (3/3) or single-phase (3/1) output, which gives it the flexibility needed to adapt to changing installation environments.
Fully galvanic isolation
Liebert NXC provides fully galvanic isolation, which means that an isolation transformer is housed in the UPS cabinet. The footprint is thus considerably reduced, which saves space. In addition, the transformer can be connected to the UPS input and/or output, and provide:
- Fully galvanic isolation for medical and other critical applications
- An installation with two independent input sources (with different neutrals)
- A power supply with no neutral
Liebert NXC features:
- 0.9 output power factor
- Energy efficiency of up to 95% in double conversion mode
- Energy efficiency in Eco mode of up to 98%
- Correction of the total harmonic distortion of the input current (THDi) < 4%
- Battery charger up to 6 kW/12 A
- Configurable three-phase/single-phase output (up to 20 kVA)
- Built-in manual bypass
- Input and output switches/circuit breakers
- Built-in parallel operation synchronization port (LBS)
| Ease of management | |||||||||
|---|---|---|---|---|---|---|---|---|---|
| Network manageable | Provides remote power management of the UPS over the network via Powerchute Business Edition. | ||||||||
| Compatible with InfraStruXure Manager | Enables centralized management via APC's InfraStruXure Manager. | ||||||||
| SmartSlot | Customize the capabilities of your UPS with management cards. | ||||||||
| LED status indicators | Gives a quick view of the power and unit status through visual indicators. | ||||||||
| Serial connectivity | Allows the UPS to be managed via a serial port. | ||||||||
| Availability | |||||||||
| Scalable runtime | Allows the runtime to be increased quickly when needed. | ||||||||
| Automatic internal bypass | Supplies mains power to the connected loads in the event of an overload or a UPS failure. | ||||||||
| Hot-swappable batteries | Ensures continuity and quality of the power supply to the protected equipment while the batteries are being replaced. | ||||||||
| Intelligent battery management | Maximizes battery performance, lifetime and reliability through an intelligent, precision charging process. | ||||||||
| Temperature-compensated battery charging | Extends battery life by regulating the charge voltage according to the actual temperature of the batteries. | ||||||||
| Automatic restart of loads after UPS shutdown | Automatically restarts the connected equipment when mains power is restored. | ||||||||
| Protection | |||||||||
| Power conditioning | Protects the connected loads against surges, spikes, lightning and other electrical disturbances. | ||||||||
| Input power factor correction | Minimizes installation costs by allowing the use of smaller generators and cables. | ||||||||
| Frequency and voltage regulation | Increases application availability by correcting abnormal frequencies and voltages without drawing on the battery. | ||||||||
| Cold start capability | Provides temporary battery power in the event of a mains failure. | ||||||||
| Generator compatible | Ensures a stable, constant supply of current to protect your equipment when a generator is used. | ||||||||
| Safety agency approved | Ensures the product has been tested and approved as able to operate safely with the connected loads and within the environment. | ||||||||
| Resettable circuit breaker | Easy recovery after a surge; no need to replace a fuse. | ||||||||
| Ease of maintenance | |||||||||
| Predictive failure notification | Provides an early-warning failure analysis function that allows components to be replaced proactively. | ||||||||
| User-replaceable batteries | Increases availability by allowing a trained user to upgrade and replace the batteries, thereby reducing repair times. | ||||||||
| Disconnected battery notification | Warns when a battery is not available to provide backup power. | ||||||||
| Audible alarms | Reports changes in mains power and UPS conditions. | ||||||||
| Automatic self-test | The battery self-test is performed periodically to ensure early detection of the need to replace a battery. | ||||||||
| Adaptability | |||||||||
| Flash-upgradable firmware | Firmware maintenance releases can be installed remotely via FTP. | ||||||||
| Rack/Tower convertible | Protects the initial investment in the UPS when migrating from a tower environment to a rack environment. | ||||||||
| Plug-and-Play external batteries | Ensures a stable, constant supply of current to the loads while the UPS runtime is being increased. | ||||||||
Other UPS in the same range
- UPS EMERSON Liebert TRI TRI / TRI MONO 10 kVA Runtime 26 min
- UPS EMERSON Liebert TRI TRI / TRI MONO 10 kVA Runtime 45 min
- UPS EMERSON Liebert TRI TRI / TRI MONO 10 kVA Runtime 65 min
- UPS EMERSON Liebert TRI TRI / TRI MONO 15 kVA Runtime 15 min
- UPS EMERSON Liebert TRI TRI / TRI MONO 15 kVA Runtime 40 min
- UPS EMERSON Liebert TRI TRI / TRI MONO 15 kVA Runtime 5 min
- UPS EMERSON Liebert TRI TRI / TRI MONO 20 kVA Runtime 10 min
- UPS EMERSON Liebert TRI TRI / TRI MONO 20 kVA Runtime 18 min