Our website is getting a makeover. Some pages may look different for a few days: orders and payments work as usual.
Our website is getting a makeover. Some pages may look different for a few days: orders and payments work as usual.
- New
Genuine APC RBC31 replacement battery
- Genuine APC replacement battery cartridge, brand new, part number RBC31
- 48 V, maintenance-free sealed lead-acid VRLA AGM
- Complete plug-and-play kit, with connectors and installation guide
- For Smart-UPS SR1 UPS units: SURT1000XLIM, SR11KXIET, SR12KXIET
- 24-month warranty
Is your APC UPS no longer providing the runtime you expect? There's no need to replace it: the APC RBC31 battery restores its energy reserve. This genuine, brand-new replacement cartridge, made by APC by Schneider Electric, is a complete, tested battery pack that replaces all of the UPS's batteries.
Key features
- Genuine APC part: it is designed for APC UPS units and their battery management, which helps preserve the performance and certifications of the device.
- Plug-and-play: a cable, all the necessary connectors and an installation guide are included.
- Hot-swappable on most APC UPS units, so there's no need to shut down the protected equipment. Check your model's user manual to confirm.
- Easy recycling: the reusable packaging and the supplied recycling guide let you send the old battery back to a suitable recycling channel.
- 24-month warranty.
What is it for?
This UPS battery is intended for both home users and professionals who want to keep an APC UPS from the Smart-UPS SR1 range in service: computer workstation, server, network equipment or any device that needs protection from power outages.
Compatible UPS units listed by Schneider Electric:
- SURT1000XLIM (Smart-UPS On-Line RT, 1000 VA, 230 V, marine)
- SR11KXIET (Smart-UPS On-Line SR1, 1000 VA)
- SR12KXIET (Smart-UPS On-Line SR1, 2000 VA)
This list is not exhaustive. If in doubt, check the battery part number on the label or in the manual of your UPS, or contact us with your UPS model number.
Technical specifications
| Specification | Value |
|---|---|
| Brand | APC |
| Part number | RBC31 |
| Product type | Replacement battery cartridge |
| Technology | Maintenance-free sealed lead-acid, VRLA AGM |
| Voltage | 48 V |
| Dimensions (W x D x H) | 165 x 419 x 70 mm |
| Net weight | 11.23 kg |
| Installation | Not rack-mountable |
| Operating temperature | 0 to 40 °C |
| Storage temperature | -15 to 45 °C |
| Relative humidity | 0 to 95% |
| Compliance | RoHS, REACH, WEEE |
| Warranty | 24 months |
Good to know
- Weighing over 11 kg, the cartridge must be handled with care during replacement.
- A datasheet and a user manual in PDF format are associated with this product.
- Used lead-acid batteries can be recycled: do not dispose of them with household waste.
| Ease of management | |||||||||
|---|---|---|---|---|---|---|---|---|---|
| Network manageable | Provides remote power management of the UPS over the network via Powerchute Business Edition. | ||||||||
| Compatible with InfraStruXure Manager | Enables centralized management via APC's InfraStruXure Manager. | ||||||||
| SmartSlot | Customize the capabilities of your UPS with management cards. | ||||||||
| LED status indicators | Gives a quick view of the power and unit status through visual indicators. | ||||||||
| Serial connectivity | Allows the UPS to be managed via a serial port. | ||||||||
| Availability | |||||||||
| Scalable runtime | Allows the runtime to be increased quickly when needed. | ||||||||
| Automatic internal bypass | Supplies mains power to the connected loads in the event of an overload or a UPS failure. | ||||||||
| Hot-swappable batteries | Ensures continuity and quality of the power supply to the protected equipment while the batteries are being replaced. | ||||||||
| Intelligent battery management | Maximizes battery performance, lifetime and reliability through an intelligent, precision charging process. | ||||||||
| Temperature-compensated battery charging | Extends battery life by regulating the charge voltage according to the actual temperature of the batteries. | ||||||||
| Automatic restart of loads after UPS shutdown | Automatically restarts the connected equipment when mains power is restored. | ||||||||
| Protection | |||||||||
| Power conditioning | Protects the connected loads against surges, spikes, lightning and other electrical disturbances. | ||||||||
| Input power factor correction | Minimizes installation costs by allowing the use of smaller generators and cables. | ||||||||
| Frequency and voltage regulation | Increases application availability by correcting abnormal frequencies and voltages without drawing on the battery. | ||||||||
| Cold start capability | Provides temporary battery power in the event of a mains failure. | ||||||||
| Generator compatible | Ensures a stable, constant supply of current to protect your equipment when a generator is used. | ||||||||
| Safety agency approved | Ensures the product has been tested and approved as able to operate safely with the connected loads and within the environment. | ||||||||
| Resettable circuit breaker | Easy recovery after a surge; no need to replace a fuse. | ||||||||
| Ease of maintenance | |||||||||
| Predictive failure notification | Provides an early-warning failure analysis function that allows components to be replaced proactively. | ||||||||
| User-replaceable batteries | Increases availability by allowing a trained user to upgrade and replace the batteries, thereby reducing repair times. | ||||||||
| Disconnected battery notification | Warns when a battery is not available to provide backup power. | ||||||||
| Audible alarms | Reports changes in mains power and UPS conditions. | ||||||||
| Automatic self-test | The battery self-test is performed periodically to ensure early detection of the need to replace a battery. | ||||||||
| Adaptability | |||||||||
| Flash-upgradable firmware | Firmware maintenance releases can be installed remotely via FTP. | ||||||||
| Rack/Tower convertible | Protects the initial investment in the UPS when migrating from a tower environment to a rack environment. | ||||||||
| Plug-and-Play external batteries | Ensures a stable, constant supply of current to the loads while the UPS runtime is being increased. | ||||||||
reducing waste and preserving our natural resources for future generations.
Every UPS that we repair or help to refurbish is one less that will end up growing our landfills.
Every battery is 97% recyclable and is a source of reusable lead.
Indeed, the lead is recovered, remelted and then refined. Once this process is complete, the recycled lead is reused to manufacture new batteries.
Lead is a precious mineral resource, and recycling it is far cheaper, both ecologically and financially, than extracting it. It is therefore an effective way of conserving natural resources and an important means of protecting our environment.
Every new replacement battery kit that we sell extends the life of your UPS for years, at a quarter of the price of a new unit.
Recycling service:
We will be happy to recycle all of your lead-acid batteries.
Our recycling program feeds the various components of used batteries back into the battery manufacturing process, recovering the hazardous lead and chemicals so that they can be reused safely.
Indeed, batteries contain lead, sulfuric acid and other chemicals that pose a health hazard and an environmental risk if they are not recycled properly. They therefore cannot be thrown away just anywhere.
Several options are available to you
You can send us your used batteries. (All shipping methods are accepted)
1. All you have to do is pack your used batteries safely.
2. Stick on the cut-out recycling image provided or available below.
3. Send them to the address shown on the label
You can go to an auto center, a garage, or a manufacturer or large retail store that sells batteries and drop them in the bins provided for that purpose.
You can also go to a waste collection center, which will know what to do with them.
At the end of the life cycle of your UPS units or your batteries, you can count on us to recycle them.