Our website is getting a makeover. Some pages may look different for a few days: orders and payments work as usual.
Our website is getting a makeover. Some pages may look different for a few days: orders and payments work as usual.
- New
Eaton 9SX 2000i Tour
- 2000 VA / 1800 W On-Line double-conversion UPS
- Pure sine wave output and automatic internal bypass
- 8 C13 outlets, LCD display, USB and RS232 ports
- Communication card slot, runtime expandable with battery modules
- Tower format, designed to protect servers
🔋 Replacement battery kit for this UPS
Convertisseur DC / AC 12 V 200 €144.00 excl. VAT€172.80 incl. VATView › The Eaton 9SX 2000i Tower UPS (part number 9SX2000I) protects your servers and sensitive equipment against power outages, micro-outages and mains disturbances. Its On-Line double-conversion technology continuously powers your devices with regenerated voltage, without passing raw mains power through. It delivers 2000 VA, or 1800 W, in a tower format.
Key features
- On-Line double conversion: your devices receive stable power, isolated from mains fluctuations.
- Pure sine wave: suited to IT and network equipment.
- Automatic internal bypass: power continuity is maintained in the event of an overload or internal fault.
- 8 C13 output outlets to connect multiple devices.
- Hot-swappable battery and automatic battery test to simplify maintenance.
- Expandable runtime: a connector allows you to add battery modules.
- Additional card slot: 1 slot for a communication card, which is not supplied as standard.
Intended use
This model is designed to power servers, storage equipment and network hardware in SMEs, equipment rooms or racks. The USB and RS232 ports allow you to monitor it and schedule the clean shutdown of your machines. The Intelligent Power Software suite is included. The LCD display shows the UPS status.
Technical specifications
| Specification | Value |
|---|---|
| Technology | On-Line double conversion |
| Power | 2000 VA / 1800 W |
| Power factor | 0.9 |
| Nominal input voltage | 230 V single-phase (range 200 to 276 V) |
| Input frequency | 40/70 Hz |
| Nominal output voltage | 230 V single-phase |
| Output frequency | 50/60 Hz |
| Waveform | Pure sine wave |
| Output outlets | 8 x C13 |
| Input connection | IEC C14 |
| Battery | Sealed lead-acid (VRLA) |
| Backup time at half load | 20 min (typical value) |
| Communication | USB, RS232, 1 additional card slot |
| Noise level | 45 dB |
| Operating temperature | 0 to 40 °C |
| Dimensions (W x D x H) | 214 x 412 x 346 mm |
| Weight | 33.3 kg |
The 9SX2000I is a UPS from the Eaton 9SX range, in black. To size your installation correctly or choose compatible battery modules, check the power requirements of your equipment before ordering.
- Type of use
- Server
- Technology
- ON-LINE Double conversion
- Output Waveform
- SineWave
- Format
- Tower
- Power in VA
- 2000
- Power in Watts
- 1800
- Width (mm)
- 214
- Display
- LCD screen
- Height (mm)
- 346
- Depth (mm)
- 412
- Weight (Kg)
- 33,3
- Input voltage
- 230V Single phase
- Output voltage
- 230V single-phase
- Expandable Autonomy
- Socket for adding battery modules
- Additional card slot
- 1 slot
- Input connector
- IEC-320-C14
- Communication port(s)
- USB + RS232
- Bypass
- Internal automatic By-Pass
Runtime according to the connected load
W
| Load (W) | Internal battery | + 1 battery module(s) | + 2 battery module(s) | + 3 battery module(s) | + 4 battery module(s) |
|---|---|---|---|---|---|
| 180 W | 1 h 40 | 8 h 11 | 15 h | 20 h | 31 h 07 |
| 360 W | 49 min | 3 h 52 | 7 h 53 | 10 h 43 | 15 h 34 |
| 540 W | 33 min | 2 h 42 | 5 h | 8 h 09 | 9 h 51 |
| 720 W | 24 min | 1 h 58 | 3 h 48 | 6 h 01 | 8 h 13 |
| 900 W | 20 min | 1 h 33 | 2 h 54 | 4 h 28 | 6 h 26 |
| 1080 W | 14 min | 1 h 12 | 2 h 21 | 3 h 31 | 4 h 44 |
| 1260 W | 12 min | 1 h 02 | 1 h 58 | 2 h 57 | 4 h 05 |
| 1440 W | 9 min | 53 min | 1 h 42 | 2 h 36 | 3 h 29 |
| 1620 W | 8 min | 45 min | 1 h 27 | 2 h 13 | 2 h 56 |
| 1800 W | 7 min | 40 min | 1 h 17 | 1 h 56 | 2 h 40 |
Typical values provided by Eaton for part number 9SX2000I. Actual runtime depends on battery age and temperature.
Technical documentation
You might also like
Other UPS in the same range
Other UPS with the same power