Eaton 9E 2000i Rack 2U
- 2,000 VA / 1,800 W on-line double-conversion UPS.
- 2U 19" rack, mounting kit (rails and brackets) included form factor.
- Output: 6 x C13.
- Hot-swappable batteries, extendable runtime.
- USB, RS232, network card slot, LCD.
The Eaton 9E 2000i Rack 2U UPS (part number 9E2000IR) is a 2,000 VA / 1,800 W on-line double-conversion UPS in a 2U 19" rack, mounting kit (rails and brackets) included form factor. It continuously supplies a stable, regulated and filtered sine wave, with zero transfer time during a power cut: the most complete protection for servers and sensitive equipment.
Key features
- 2,000 VA / 1,800 W, regulated sine wave output.
- Up to 91 % efficiency in double-conversion mode.
- Outputs: 6 x C13.
- Hot-swappable batteries, without powering down protected equipment.
- Extendable runtime with the 9EEBM72R battery module.
- USB and RS232 ports, slot for an optional network card, remote shutdown.
- LCD to monitor UPS status and measurements.
What is it for?
For 19" racks in small IT rooms and network cabinets: it mounts in 2U with the supplied kit.
Technical specifications
| General | |
|---|---|
| Part number | 9E2000IR |
| Range | Eaton 9E |
| Power | 2,000 VA / 1,800 W |
| Form factor | 2U 19" rack, mounting kit (rails and brackets) included |
| Dimensions (W x D x H) | 438 x 608 x 86.5 mm |
| Weight | 29.9 kg |
| Warranty | 2 years |
| Input | |
| Nominal voltage | 230 V single-phase |
| Voltage range | 176 to 300 V (100 to 300 V with derating) |
| Frequency | 50 / 60 Hz |
| Connection | C14 inlet |
| Output | |
| Topology | On-line double conversion |
| Output voltage | 230 V single-phase (200 / 208 / 220 / 230 / 240 V) |
| Power factor | 0.9 |
| Waveform | Pure sine wave |
| Outputs | 6 x C13 |
| Efficiency (online) | 91 % |
| Bypass | Automatic internal bypass |
| Battery | |
| Type | Valve-regulated lead-acid (VRLA) |
| Batteries | 6 x 12 V / 7 Ah |
| Replacement | Hot-swappable |
| Runtime extension | Yes, with the 9EEBM72R battery module |
| Communication | |
| Ports | USB (HID compatible), RS232 serial |
| Card slot | 1 slot for an optional communication card (network, relay) |
| Display | LCD |
| Environment | |
| Operating temperature | 0 to 40 °C |
| Noise level | < 45 dB at 1 m |
| Compliance | |
| Standards and certifications | IEC/EN 62040-1, IEC/EN 62040-2, CE |
Source: Eaton specifications. Runtime depends on load, battery age and temperature.
- Type of use
- Server
- Technology
- ON-LINE Double conversion
- Output Waveform
- SineWave
- Format
- 19" Rack
- Power in VA
- 2000
- Power in Watts
- 1800
- Width (mm)
- 438
- Display
- LCD screen
- Height (mm)
- 86,5
- Depth (mm)
- 608
- Weight (Kg)
- 29.9
- Rack
- 2 U
- Rail kit included
- Yes
- Input voltage
- 230V Single phase
- Output voltage
- 230V single-phase
- Expandable Autonomy
- Socket for adding battery modules
- Redondancy
- No
- Additional card slot
- 1 slot
- Input connector
- IEC-320-C14
- Communication port(s)
- USB + RS232
- Bypass
- Internal automatic By-Pass
- Warranty
- 2 years
Runtime according to the connected load
W
| Load (W) | Internal battery | + 1 battery module(s) | + 2 battery module(s) | + 3 battery module(s) | + 4 battery module(s) |
|---|---|---|---|---|---|
| 180 W | 1 h 10 | 5 h 41 | 9 h 52 | 16 h 04 | 19 h 43 |
| 360 W | 36 min | 2 h 54 | 5 h 47 | 8 h 42 | 11 h 07 |
| 540 W | 23 min | 1 h 52 | 3 h 34 | 5 h 28 | 7 h 47 |
| 720 W | 17 min | 1 h 22 | 2 h 38 | 3 h 57 | 5 h 26 |
| 900 W | 12 min | 1 h 03 | 1 h 59 | 2 h 58 | 4 h 09 |
| 1080 W | 9 min | 51 min | 1 h 38 | 2 h 31 | 3 h 21 |
| 1260 W | 7 min | 42 min | 1 h 22 | 2 h 03 | 2 h 49 |
| 1440 W | 6 min | 36 min | 1 h 10 | 1 h 47 | 2 h 27 |
| 1620 W | 5 min | 34 min | 1 h 05 | 1 h 39 | 2 h 16 |
| 1800 W | 4 min | 30 min | 58 min | 1 h 28 | 1 h 58 |
Typical values provided by Eaton for part number 9E2000IR. Actual runtime depends on battery age and temperature.