Eaton 9SX 5000i RT3U G2
- 5000 VA / 5000 W On-Line double conversion UPS for computer rooms and server racks.
- Pure sine wave output, automatic internal by-pass and runtime extendable with battery modules.
- 3U rack-mountable, 8 C13 outlets and 3 C19 outlets, rack mounting kit included.
🔋 Replacement battery kit for this UPS
Battery kit for UPS EATON 9SX 5000i RT3U G2 9SX5KIRT3UG2 €255.00 excl. VAT€306.00 incl. VATView › The Eaton 9SX 5000i RT3U G2 UPS (reference 9SX5KIRT3UG2) protects your sensitive IT equipment against power outages and mains disturbances. Its On-Line double conversion topology continuously supplies your devices with regenerated voltage, with a capacity of 5000 VA / 5000 W. It is part of the Eaton 9SX Gen2 range.
Key features
- On-Line double conversion: the output is isolated from mains variations.
- Pure sine wave output, suited to demanding electronic loads.
- Automatic internal by-pass to maintain power in case of UPS fault.
- Extendable runtime thanks to a dedicated port for adding battery modules.
- Multilingual LCD display to monitor the UPS status.
- Communication via USB (HID compatible) and RS232 ports, with a slot for an expansion card.
What is it used for?
This UPS is designed for computer rooms and rack installations. Its 3U format mounts in a rack with the supplied mounting kit, or can be used as a tower thanks to the included supports. The input is connected via terminal block. The outputs provide 8 C13 outlets, 3 C19 outlets and hard-wired outputs, for easy power distribution to your equipment.
Technical specifications
| Specification | Value |
|---|---|
| Brand / reference | Eaton / 9SX5KIRT3UG2 |
| Topology | On-Line double conversion |
| Power | 5000 VA / 5000 W |
| Input voltage | 230 V single-phase (range 176 - 276 V, 100 - 276 V with derating) |
| Output voltage | 230 V single-phase (200 to 240 V selectable) |
| Waveform | Sine wave |
| Input frequency | 40 - 70 Hz |
| Efficiency | 96.7 % |
| Crest factor | 3:1 |
| Output sockets | 8 x C13, 3 x C19, hard-wired outputs |
| Battery | Sealed lead-acid (VRLA), 15 batteries 12 V / 5 Ah |
| Communication | USB + RS232, 1 expansion card slot |
| Form factor | 3U, rack/tower |
| Noise level | < 40 dB at 1 metre |
| Operating temperature | 0 - 40 °C |
| Dimensions (W x D x H) | 440 x 130 x 684 mm |
| Weight | 43.1 kg |
- Type of use
- IT room
- Technology
- ON-LINE Double conversion
- Output Waveform
- SineWave
- Format
- Rack/tower convertible (rails included)
- Power in VA
- 5000
- Power in Watts
- 5000
- Width (mm)
- 440
- Display
- LCD screen
- Height (mm)
- 130
- Depth (mm)
- 684
- Weight (Kg)
- 43,1
- Rack
- 3 U
- Rail kit included
- Yes
- Input voltage
- 230V Single phase
- Output voltage
- 230V single-phase
- Expandable Autonomy
- Socket for adding battery modules
- Redondancy
- No
- Additional card slot
- 1 slot
- Input connector
- Hardwired
- Communication port(s)
- USB + RS232
- Bypass
- Internal automatic By-Pass
- Warranty
- 2 years
Runtime according to the connected load
W
| Load (W) | Internal battery | + 1 battery module(s) | + 2 battery module(s) | + 3 battery module(s) | + 4 battery module(s) | + 5 battery module(s) | + 6 battery module(s) | + 7 battery module(s) | + 8 battery module(s) | + 9 battery module(s) | + 10 battery module(s) | + 11 battery module(s) | + 12 battery module(s) |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 250 W | 2 h 11 | 7 h 22 | 13 h 23 | 9 h 55 | 13 h 22 | 17 h 07 | 9 h 44 | 11 h 31 | 13 h 22 | 15 h 19 | 17 h 20 | 19 h 27 | 13 h 27 |
| 500 W | 1 h 07 | 3 h 49 | 6 h 45 | 9 h 55 | 13 h 22 | 17 h 07 | 9 h 44 | 11 h 31 | 13 h 22 | 15 h 19 | 17 h 20 | 19 h 27 | 13 h 27 |
| 1000 W | 30 min | 1 h 53 | 3 h 20 | 4 h 50 | 6 h 23 | 8 h 01 | 9 h 44 | 11 h 31 | 13 h 22 | 15 h 19 | 17 h 20 | 19 h 27 | 13 h 27 |
| 1450 W | 19 min | 1 h 17 | 2 h 18 | 3 h 20 | 4 h 24 | 5 h 31 | 6 h 39 | 7 h 50 | 9 h 02 | 10 h 18 | 11 h 34 | 12 h 55 | 13 h 27 |
| 1950 W | 13 min | 54,1 min | 1 h 39 | 2 h 24 | 3 h 11 | 3 h 58 | 4 h 47 | 5 h 36 | 6 h 27 | 7 h 19 | 8 h 12 | 9 h 07 | 10 h 02 |
| 2500 W | 9 min | 39 min | 1 h 13 | 1 h 48 | 2 h 24 | 3 h | 3 h 36 | 4 h 13 | 4 h 51 | 5 h 30 | 6 h 09 | 6 h 49 | 7 h 29 |
| 3000 W | 7 min | 31 min | 59 min | 1 h 28 | 1 h 57 | 2 h 27 | 2 h 57 | 3 h 27 | 3 h 58 | 4 h 30 | 5 h 01 | 5 h 33 | 6 h 06 |
| 3500 W | 6 min | 26 min | 50 min | 1 h 14 | 1 h 40 | 2 h 05 | 2 h 31 | 2 h 58 | 3 h 25 | 3 h 52 | 4 h 19 | 4 h 47 | 5 h 15 |
| 3950 W | 5 min | 22,4 min | 42,8 min | 1 h 05 | 1 h 27 | 1 h 50 | 2 h 12 | 2 h 36 | 2 h 59 | 3 h 22 | 3 h 47 | 4 h 11 | 4 h 35 |
| 4600 W | 4 min | 18,4 min | 35,2 min | 53,6 min | 1 h 12 | 1 h 32 | 1 h 51 | 2 h 11 | 2 h 31 | 2 h 51 | 3 h 11 | 3 h 31 | 3 h 52 |
| 5000 W | 3 min | 16 min | 32 min | 48 min | 1 h 06 | 1 h 23 | 1 h 41 | 1 h 58 | 2 h 17 | 2 h 35 | 2 h 53 | 3 h 12 | 3 h 30 |
Typical values provided by Eaton for part number 9SX5KIRT3UG2. Actual runtime depends on battery age and temperature.