  • 3,000 VA / 2,400 W on-line double-conversion UPS.
  • Tower form factor.
  • Output: 6 x C13 + 1 x C19.
  • Hot-swappable batteries, extendable runtime.
  • USB, RS232, network card slot, LCD.
9E3000I
Price on request

The price of this product is available on request. Click “Contact us” and we will quickly send you our best offer.

 

The Eaton 9E 3000i Tour UPS (part number 9E3000I) is a 3,000 VA / 2,400 W on-line double-conversion UPS in a tower form factor. It continuously supplies a stable, regulated and filtered sine wave, with zero transfer time during a power cut: the most complete protection for servers and sensitive equipment.

Key features

  • 3,000 VA / 2,400 W, regulated sine wave output.
  • Up to 91 % efficiency in double-conversion mode.
  • Outputs: 6 x C13 + 1 x C19.
  • Hot-swappable batteries, without powering down protected equipment.
  • Extendable runtime with the 9EEBM72 battery module.
  • USB and RS232 ports, slot for an optional network card, remote shutdown.
  • LCD to monitor UPS status and measurements.

What is it for?

To protect a server, a NAS, sensitive workstations or a small network in offices, shops and medical practices. It stands on the floor or a shelf and plugs into a wall socket.

Technical specifications

General
Part number9E3000I
EAN0786689166588
RangeEaton 9E
Power3,000 VA / 2,400 W
Form factorTower
Dimensions (W x D x H)190 x 399 x 330 mm
Weight24.2 kg
Warranty2 years
Input
Nominal voltage230 V single-phase
Voltage range176 to 300 V (100 to 300 V with derating)
Frequency50 / 60 Hz
ConnectionC20 inlet
Output
TopologyOn-line double conversion
Output voltage230 V single-phase (200 / 208 / 220 / 230 / 240 V)
Power factor0.8
WaveformPure sine wave
Outputs6 x C13 + 1 x C19
Efficiency (online)91 %
BypassAutomatic internal bypass
Battery
TypeValve-regulated lead-acid (VRLA)
Batteries6 x 12 V / 9 Ah
ReplacementHot-swappable
Runtime extensionYes, with the 9EEBM72 battery module
Communication
PortsUSB (HID compatible), RS232 serial
Card slot1 slot for an optional communication card (network, relay)
DisplayLCD
Environment
Operating temperature0 to 40 °C
Noise level< 37 dB at 1 m
Compliance
Standards and certificationsIEC/EN 62040-1, IEC/EN 62040-2, CE, EAC

Source: Eaton specifications. Runtime depends on load, battery age and temperature.

Type of use
Server
Technology
ON-LINE Double conversion
Output Waveform
SineWave
Format
Tower
Power in VA
3000
Power in Watts
2400
Width (mm)
190
Display
LCD screen
Height (mm)
330
Depth (mm)
399
Weight (Kg)
24.2
Input voltage
230V Single phase
Output voltage
230V single-phase
Expandable Autonomy
Socket for adding battery modules
Redondancy
No
Additional card slot
1 slot
Input connector
IEC-320-C20
Communication port(s)
USB + RS232
Bypass
Internal automatic By-Pass
Warranty
2 years
0786689166588
9E3000I

Click here to leave a review


Be the first to ask a question about this product!


Question about the product

* Required fields
(read)

Runtime according to the connected load

0050050010001000150015002000200025002500Load of the connected equipment (W)Runtime (minutes)120 W : 3 h240 W : 1 h 25360 W : 54 min480 W : 41 min720 W : 26 min972 W : 18 min1231 W : 13 min1452 W : 10 min1680 W : 8 min1848 W : 7 min2052 W : 6 min2280 W : 5 min2400 W : 4 min120 W : 11 h 39240 W : 4 h 30360 W : 3 h 05480 W : 2 h 17600 W : 1 h 47720 W : 1 h 28840 W : 1 h 16960 W : 1 h 051080 W : 56 min1200 W : 49 min1320 W : 43 min1440 W : 41 min1560 W : 38 min1680 W : 35 min1800 W : 31 min1920 W : 29 min2040 W : 27 min2160 W : 25 min2280 W : 23 min2400 W : 22 min120 W : 22 h240 W : 8 h 48360 W : 5 h 30480 W : 3 h 49600 W : 3 h 10720 W : 2 h 36840 W : 2 h 06960 W : 1 h 511080 W : 1 h 401200 W : 1 h 301320 W : 1 h 231440 W : 1 h 161560 W : 1 h 091680 W : 1 h 021800 W : 57 min1920 W : 52 min2040 W : 48 min2160 W : 44 min2280 W : 43 min2400 W : 41 min120 W : 35 h 43240 W : 13 h 34360 W : 8 h480 W : 6 h600 W : 4 h 21720 W : 3 h 36840 W : 3 h 09960 W : 2 h 461080 W : 2 h 251200 W : 2 h 051320 W : 1 h 541440 W : 1 h 461560 W : 1 h 381680 W : 1 h 311800 W : 1 h 251920 W : 1 h 202040 W : 1 h 152160 W : 1 h 102280 W : 1 h 052400 W : 1 h120 W : 40 h240 W : 18 h 20360 W : 12 h 02480 W : 7 h 55600 W : 6 h 13720 W : 4 h 49840 W : 3 h 53960 W : 3 h 321080 W : 3 h 111200 W : 2 h 531320 W : 2 h 371440 W : 2 h 201560 W : 2 h 051680 W : 1 h 551800 W : 1 h 491920 W : 1 h 432040 W : 1 h 372160 W : 1 h 312280 W : 1 h 262400 W : 1 h 22
Internal battery+ 1 battery module(s)+ 2 battery module(s)+ 3 battery module(s)+ 4 battery module(s)

W

Load (W)Internal battery+ 1 battery module(s)+ 2 battery module(s)+ 3 battery module(s)+ 4 battery module(s)
120 W3 h11 h 3922 h35 h 4340 h
240 W1 h 254 h 308 h 4813 h 3418 h 20
360 W54 min3 h 055 h 308 h12 h 02
480 W41 min2 h 173 h 496 h7 h 55
720 W26 min1 h 282 h 363 h 364 h 49
972 W18 min1 h 041 h 502 h 443 h 30
1231 W13 min47,5 min1 h 282 h 022 h 49
1452 W10 min40,7 min1 h 151 h 452 h 19
1680 W8 min35 min1 h 021 h 311 h 55
1848 W7 min30,2 min55 min1 h 231 h 47
2052 W6 min26,8 min47,6 min1 h 151 h 36
2280 W5 min23 min43 min1 h 051 h 26
2400 W4 min22 min41 min1 h1 h 22