- New
Eaton 9E 2000i Tour
- 2,000 VA / 1,600 W on-line double-conversion UPS.
- Tower form factor.
- Output: 6 x C13.
- Hot-swappable batteries, extendable runtime.
- USB, RS232, network card slot, LCD.
The Eaton 9E 2000i Tour UPS (part number 9E2000I) is a 2,000 VA / 1,600 W on-line double-conversion UPS in a tower form factor. It continuously supplies a stable, regulated and filtered sine wave, with zero transfer time during a power cut: the most complete protection for servers and sensitive equipment.
Key features
- 2,000 VA / 1,600 W, regulated sine wave output.
- Up to 91 % efficiency in double-conversion mode.
- Outputs: 6 x C13.
- Hot-swappable batteries, without powering down protected equipment.
- Extendable runtime with the 9EEBM72 battery module.
- USB and RS232 ports, slot for an optional network card, remote shutdown.
- LCD to monitor UPS status and measurements.
What is it for?
To protect a server, a NAS, sensitive workstations or a small network in offices, shops and medical practices. It stands on the floor or a shelf and plugs into a wall socket.
Technical specifications
| General | |
|---|---|
| Part number | 9E2000I |
| EAN | 0786689166571 |
| Range | Eaton 9E |
| Power | 2,000 VA / 1,600 W |
| Form factor | Tower |
| Dimensions (W x D x H) | 190 x 399 x 330 mm |
| Weight | 15.8 kg |
| Warranty | 2 years |
| Input | |
| Nominal voltage | 230 V single-phase |
| Voltage range | 176 to 300 V (100 to 300 V with derating) |
| Frequency | 50 / 60 Hz |
| Connection | C14 inlet |
| Output | |
| Topology | On-line double conversion |
| Output voltage | 230 V single-phase (200 / 208 / 220 / 230 / 240 V) |
| Power factor | 0.8 |
| Waveform | Pure sine wave |
| Outputs | 6 x C13 |
| Efficiency (online) | 91 % |
| Bypass | Automatic internal bypass |
| Battery | |
| Type | Valve-regulated lead-acid (VRLA) |
| Batteries | 6 x 12 V / 7 Ah |
| Replacement | Hot-swappable |
| Runtime extension | Yes, with the 9EEBM72 battery module |
| Communication | |
| Ports | USB (HID compatible), RS232 serial |
| Card slot | 1 slot for an optional communication card (network, relay) |
| Display | LCD |
| Environment | |
| Operating temperature | 0 to 40 °C |
| Noise level | < 37 dB at 1 m |
| Compliance | |
| Standards and certifications | IEC/EN 62040-1, IEC/EN 62040-2, CE, EAC |
Source: Eaton specifications. Runtime depends on load, battery age and temperature.
- Type of use
- Server
- Technology
- ON-LINE Double conversion
- Output Waveform
- SineWave
- Format
- Tower
- Power in VA
- 2000
- Power in Watts
- 1600
- Width (mm)
- 190
- Display
- LCD screen
- Height (mm)
- 330
- Depth (mm)
- 399
- Weight (Kg)
- 15.8
- Input voltage
- 230V Single phase
- Output voltage
- 230V single-phase
- Expandable Autonomy
- Socket for adding battery modules
- Redondancy
- No
- Additional card slot
- 1 slot
- Input connector
- IEC-320-C14
- Communication port(s)
- USB + RS232
- Bypass
- Internal automatic By-Pass
- Warranty
- 2 years
Runtime according to the connected load
W
| Load (W) | Internal battery | + 1 battery module(s) | + 2 battery module(s) | + 3 battery module(s) | + 4 battery module(s) |
|---|---|---|---|---|---|
| 160 W | 1 h 43 | 6 h 04 | 11 h 54 | 17 h 32 | 26 h 43 |
| 320 W | 52 min | 3 h 08 | 5 h 32 | 8 h 28 | 12 h 05 |
| 400 W | 41 min | 2 h 32 | 4 h 10 | 6 h 34 | 9 h 06 |
| 488 W | 32 min | 1 h 59 | 3 h 33 | 5 h 13 | 7 h 06 |
| 648 W | 22 min | 1 h 35 | 2 h 50 | 3 h 52 | 5 h 27 |
| 712 W | 18 min | 1 h 27 | 2 h 36 | 3 h 37 | 4 h 50 |
| 816 W | 16 min | 1 h 17 | 2 h 12 | 3 h 14 | 3 h 60 |
| 912 W | 14 min | 1 h 08 | 1 h 56 | 2 h 55 | 3 h 42 |
| 1024 W | 12 min | 57,6 min | 1 h 45 | 2 h 35 | 3 h 21 |
| 1104 W | 11 min | 52,8 min | 1 h 38 | 2 h 22 | 3 h 07 |
| 1184 W | 10 min | 48,8 min | 1 h 30 | 2 h 09 | 2 h 55 |
| 1280 W | 9 min | 44,8 min | 1 h 24 | 1 h 57 | 2 h 43 |
| 1408 W | 8 min | 40,8 min | 1 h 17 | 1 h 48 | 2 h 25 |
| 1520 W | 7 min | 38,2 min | 1 h 10 | 1 h 41 | 2 h 10 |
| 1600 W | 6 min | 35 min | 1 h 05 | 1 h 35 | 1 h 59 |
Typical values provided by Eaton for part number 9E2000I. Actual runtime depends on battery age and temperature.