Eaton 9E 6000i Tour
- 6,000 VA / 4,800 W on-line double-conversion UPS.
- Tower form factor.
- Output: hardwired terminal block.
- Hot-swappable batteries, extendable runtime.
- USB, RS232, network card slot, LCD.
The Eaton 9E 6000i Tour UPS (part number 9E6Ki) is a 6,000 VA / 4,800 W on-line double-conversion UPS in a tower form factor. It continuously supplies a stable, regulated and filtered sine wave, with zero transfer time during a power cut: the most complete protection for servers and sensitive equipment.
Key features
- 6,000 VA / 4,800 W, regulated sine wave output.
- Up to 91 % efficiency in double-conversion mode.
- Outputs: hardwired terminal block.
- Hot-swappable batteries, without powering down protected equipment.
- Extendable runtime with the 9EEBM180 battery module.
- USB and RS232 ports, slot for an optional network card, remote shutdown.
- LCD to monitor UPS status and measurements.
What is it for?
For server rooms, industrial equipment and high-power critical installations. Input and output are hardwired and require a suitable electrical installation (electrician).
Technical specifications
| General | |
|---|---|
| Part number | 9E6Ki |
| EAN | 0743172067661 |
| Range | Eaton 9E |
| Power | 6,000 VA / 4,800 W |
| Form factor | Tower |
| Dimensions (W x D x H) | 262 x 613 x 709 mm |
| Weight | 68 kg |
| Warranty | 2 years |
| Input | |
| Nominal voltage | 230 V single-phase |
| Voltage range | 176 to 276 V (110 to 276 V with derating) |
| Frequency | 50 / 60 Hz |
| Connection | Hardwired terminal block |
| Output | |
| Topology | On-line double conversion |
| Output voltage | 230 V single-phase (200 / 208 / 220 / 230 / 240 V) |
| Power factor | 0.8 |
| Waveform | Pure sine wave |
| Outputs | hardwired terminal block |
| Efficiency (online) | 91 % |
| Bypass | Automatic internal bypass |
| Battery | |
| Type | Valve-regulated lead-acid (VRLA) |
| Batteries | 15 x 12 V / 9 Ah |
| Replacement | Hot-swappable |
| Runtime extension | Yes, with the 9EEBM180 battery module |
| Communication | |
| Ports | USB (HID compatible), RS232 serial |
| Card slot | 1 slot for an optional communication card (network, relay) |
| Display | LCD |
| Environment | |
| Operating temperature | 0 to 40 °C |
| Noise level | < 55 dB at 1 m |
| Compliance | |
| Standards and certifications | IEC/EN 62040-1, IEC/EN 62040-2, CE, EAC |
Source: Eaton specifications. Runtime depends on load, battery age and temperature.
- Type of use
- IT room
- Technology
- ON-LINE Double conversion
- Output Waveform
- SineWave
- Format
- Tower
- Power in VA
- 6000
- Power in Watts
- 4800
- Width (mm)
- 262
- Display
- LCD screen
- Height (mm)
- 709
- Depth (mm)
- 613
- Weight (Kg)
- 68
- Input voltage
- 230V Single phase
- Output voltage
- 230V single-phase
- Expandable Autonomy
- Socket for adding battery modules
- Redondancy
- No
- Additional card slot
- 1 slot
- Input connector
- Hardwired
- Communication port(s)
- USB + RS232
- Bypass
- Internal automatic By-Pass
- Warranty
- 2 years
Runtime according to the connected load
W
| Load (W) | Internal battery | + 1 battery module(s) | + 2 battery module(s) | + 3 battery module(s) | + 4 battery module(s) |
|---|---|---|---|---|---|
| 576 W | 1 h 55 | 7 h 34 | 11 h 46 | 17 h 52 | 24 h 24 |
| 1200 W | 41 min | 2 h 42 | 4 h 12 | 6 h 23 | 8 h 43 |
| 1776 W | 28 min | 1 h 50 | 2 h 45 | 4 h 11 | 5 h 42 |
| 2400 W | 19 min | 1 h 15 | 1 h 47 | 2 h 43 | 3 h 42 |
| 3024 W | 14 min | 58 min | 1 h 25 | 2 h 08 | 2 h 53 |
| 3600 W | 11 min | 47 min | 1 h 10 | 1 h 44 | 2 h 20 |
| 4176 W | 9 min | 40 min | 1 h | 1 h 28 | 1 h 59 |
| 4800 W | 8 min | 33 min | 50 min | 1 h 14 | 1 h 40 |
Typical values provided by Eaton for part number 9E6KI. Actual runtime depends on battery age and temperature.