Our website is getting a makeover. Some pages may look different for a few days: orders and payments work as usual.
Our website is getting a makeover. Some pages may look different for a few days: orders and payments work as usual.
- New
Eaton 9E 1000i Tour
- 1,000 VA / 800 W on-line double-conversion UPS.
- Tower form factor.
- Output: 4 x C13.
- Hot-swappable batteries, extendable runtime.
- USB, RS232, network card slot, LCD.
The Eaton 9E 1000i Tour UPS (part number 9E1000I) is a 1,000 VA / 800 W on-line double-conversion UPS in a tower form factor. It continuously supplies a stable, regulated and filtered sine wave, with zero transfer time during a power cut: the most complete protection for servers and sensitive equipment.
Key features
- 1,000 VA / 800 W, regulated sine wave output.
- Up to 94 % efficiency in double-conversion mode.
- Outputs: 4 x C13.
- Hot-swappable batteries, without powering down protected equipment.
- Extendable runtime with Eaton external battery modules.
- USB and RS232 ports, slot for an optional network card, remote shutdown.
- LCD to monitor UPS status and measurements.
What is it for?
To protect a server, a NAS, sensitive workstations or a small network in offices, shops and medical practices. It stands on the floor or a shelf and plugs into a wall socket.
Technical specifications
| General | |
|---|---|
| Part number | 9E1000I |
| EAN | 0786689166564 |
| Range | Eaton 9E |
| Power | 1,000 VA / 800 W |
| Form factor | Tower |
| Dimensions (W x D x H) | 144 x 356 x 228 mm |
| Weight | 9.5 kg |
| Warranty | 2 years |
| Input | |
| Nominal voltage | 230 V single-phase |
| Voltage range | 176 to 300 V (100 to 300 V with derating) |
| Frequency | 50 / 60 Hz |
| Connection | C14 inlet |
| Output | |
| Topology | On-line double conversion |
| Output voltage | 230 V single-phase (200 / 208 / 220 / 230 / 240 V) |
| Power factor | 0.8 |
| Waveform | Pure sine wave |
| Outputs | 4 x C13 |
| Efficiency (online) | 94 % |
| Bypass | Automatic internal bypass |
| Battery | |
| Type | Valve-regulated lead-acid (VRLA) |
| Batteries | 2 x 12 V / 9 Ah |
| Replacement | Hot-swappable |
| Runtime extension | Yes, with external battery modules |
| Communication | |
| Ports | USB (HID compatible), RS232 serial |
| Card slot | 1 slot for an optional communication card (network, relay) |
| Display | LCD |
| Environment | |
| Operating temperature | 0 to 40 °C |
| Noise level | < 37 dB at 1 m |
| Compliance | |
| Standards and certifications | IEC/EN 62040-1, IEC/EN 62040-2, CE, EAC |
Source: Eaton specifications. Runtime depends on load, battery age and temperature.
- Type of use
- Server
- Technology
- ON-LINE Double conversion
- Output Waveform
- SineWave
- Format
- Tower
- Power in VA
- 1000
- Power in Watts
- 800
- Width (mm)
- 144
- Display
- LCD screen
- Height (mm)
- 228
- Depth (mm)
- 356
- Weight (Kg)
- 9.5
- Input voltage
- 230V Single phase
- Output voltage
- 230V single-phase
- Expandable Autonomy
- Socket for adding battery modules
- Redondancy
- No
- Additional card slot
- 1 slot
- Input connector
- IEC-320-C14
- Communication port(s)
- USB + RS232
- Bypass
- Internal automatic By-Pass
- Warranty
- 2 years
Runtime according to the connected load
W
| Load (W) | Runtime |
|---|---|
| 40 W | 1 h 57 |
| 80 W | 56 min |
| 128 W | 40 min |
| 160 W | 30 min |
| 208 W | 24 min |
| 248 W | 21 min |
| 280 W | 17 min |
| 332 W | 14 min |
| 388 W | 12 min |
| 416 W | 11 min |
| 444 W | 10 min |
| 472 W | 9 min |
| 516 W | 8 min |
| 556 W | 7 min |
| 648 W | 6 min |
| 748 W | 5 min |
| 800 W | 4 min |
Typical values provided by Eaton for part number 9E1000I. Actual runtime depends on battery age and temperature.